unleashed-firmware/firmware/targets/f6/ble-glue/battery_service.c
Anna Prosvetova 558fa5670b
RPC: Add Virtual Display & Unify log tags (#814)
* RPC: Update protobuf sources
* RPC: Add Virtual Display
* Unify log tags
* RPC: Virtual Display placeholder
* Rpc: clear frame buffer callback before confirm.
* Firmware: full assert for hal, move fatfs initialization to furi hal.
* FuriHal: VCP optimizations, thread safe console. Rpc: adjust buffer sizes.

Co-authored-by: Aleksandr Kutuzov <alleteam@gmail.com>
2021-11-12 16:04:35 +03:00

79 lines
2.7 KiB
C

#include "battery_service.h"
#include "app_common.h"
#include "ble.h"
#include <furi.h>
#define TAG "BtBatterySvc"
typedef struct {
uint16_t svc_handle;
uint16_t char_level_handle;
} BatterySvc;
static BatterySvc* battery_svc = NULL;
static const uint16_t service_uuid = BATTERY_SERVICE_UUID;
static const uint16_t char_battery_level_uuid = BATTERY_LEVEL_CHAR_UUID;
void battery_svc_start() {
battery_svc = furi_alloc(sizeof(BatterySvc));
tBleStatus status;
// Add Battery service
status = aci_gatt_add_service(UUID_TYPE_16, (Service_UUID_t*)&service_uuid, PRIMARY_SERVICE, 4, &battery_svc->svc_handle);
if(status) {
FURI_LOG_E(TAG, "Failed to add Battery service: %d", status);
}
// Add Battery level characteristic
status = aci_gatt_add_char(battery_svc->svc_handle,
UUID_TYPE_16,
(Char_UUID_t *) &char_battery_level_uuid,
1,
CHAR_PROP_READ | CHAR_PROP_NOTIFY,
ATTR_PERMISSION_AUTHEN_READ,
GATT_DONT_NOTIFY_EVENTS,
10,
CHAR_VALUE_LEN_CONSTANT,
&battery_svc->char_level_handle);
if(status) {
FURI_LOG_E(TAG, "Failed to add Battery level characteristic: %d", status);
}
}
void battery_svc_stop() {
tBleStatus status;
if(battery_svc) {
// Delete Battery level characteristic
status = aci_gatt_del_char(battery_svc->svc_handle, battery_svc->char_level_handle);
if(status) {
FURI_LOG_E(TAG, "Failed to delete Battery level characteristic: %d", status);
}
// Delete Battery service
status = aci_gatt_del_service(battery_svc->svc_handle);
if(status) {
FURI_LOG_E(TAG, "Failed to delete Battery service: %d", status);
}
free(battery_svc);
battery_svc = NULL;
}
}
bool battery_svc_update_level(uint8_t battery_charge) {
// Check if service was started
if(battery_svc == NULL) {
return false;
}
// Update battery level characteristic
FURI_LOG_I(TAG, "Updating battery level characteristic");
tBleStatus result = aci_gatt_update_char_value(battery_svc->svc_handle,
battery_svc->char_level_handle,
0,
1,
&battery_charge);
if(result) {
FURI_LOG_E(TAG, "Failed updating RX characteristic: %d", result);
}
return result != BLE_STATUS_SUCCESS;
}