unleashed-firmware/applications/plugins/unitemp/sensors/LM75.c
2022-12-19 20:16:02 +03:00

88 lines
2.9 KiB
C

/*
Unitemp - Universal temperature reader
Copyright (C) 2022 Victor Nikitchuk (https://github.com/quen0n)
This program is free software: you can redistribute it and/or modify
it under the terms of the GNU General Public License as published by
the Free Software Foundation, either version 3 of the License, or
(at your option) any later version.
This program is distributed in the hope that it will be useful,
but WITHOUT ANY WARRANTY; without even the implied warranty of
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
GNU General Public License for more details.
You should have received a copy of the GNU General Public License
along with this program. If not, see <https://www.gnu.org/licenses/>.
*/
#include "LM75.h"
#include "../interfaces/I2CSensor.h"
#define LM75_REG_TEMP 0x00
#define LM75_REG_CONFIG 0x01
#define LM75_REG_THYST 0x02
#define LM75_REG_TOS 0x03
#define LM75_CONFIG_SHUTDOWN 0b00000001
#define LM75_CONFIG_INTERRUPT 0b00000010
#define LM75_CONFIG_OSPOLARITY_HIGH 0b00000100
#define LM75_CONFIG_FAULTQUEUE_1 0b00000000
#define LM75_CONFIG_FAULTQUEUE_2 0b00001000
#define LM75_CONFIG_FAULTQUEUE_4 0b00010000
#define LM75_CONFIG_FAULTQUEUE_6 0b00011000
const SensorType LM75 = {
.typename = "LM75",
.interface = &I2C,
.datatype = UT_DATA_TYPE_TEMP,
.pollingInterval = 500,
.allocator = unitemp_LM75_alloc,
.mem_releaser = unitemp_LM75_free,
.initializer = unitemp_LM75_init,
.deinitializer = unitemp_LM75_deinit,
.updater = unitemp_LM75_update};
bool unitemp_LM75_alloc(Sensor* sensor, char* args) {
UNUSED(args);
I2CSensor* i2c_sensor = (I2CSensor*)sensor->instance;
//Адреса на шине I2C (7 бит)
i2c_sensor->minI2CAdr = 0b1001000 << 1;
i2c_sensor->maxI2CAdr = 0b1001111 << 1;
return true;
}
bool unitemp_LM75_free(Sensor* sensor) {
//Нечего высвобождать, так как ничего не было выделено
UNUSED(sensor);
return true;
}
bool unitemp_LM75_init(Sensor* sensor) {
I2CSensor* i2c_sensor = (I2CSensor*)sensor->instance;
//Выход если не удалось записать значение в датчик
if(!unitemp_i2c_writeReg(i2c_sensor, LM75_REG_CONFIG, LM75_CONFIG_FAULTQUEUE_1)) return false;
return true;
}
bool unitemp_LM75_deinit(Sensor* sensor) {
I2CSensor* i2c_sensor = (I2CSensor*)sensor->instance;
if(!unitemp_i2c_writeReg(
i2c_sensor, LM75_REG_CONFIG, LM75_CONFIG_FAULTQUEUE_1 | LM75_CONFIG_SHUTDOWN))
return false;
return true;
}
UnitempStatus unitemp_LM75_update(Sensor* sensor) {
I2CSensor* i2c_sensor = (I2CSensor*)sensor->instance;
uint8_t buff[2];
if(!unitemp_i2c_readRegArray(i2c_sensor, LM75_REG_TEMP, 2, buff))
return UT_SENSORSTATUS_TIMEOUT;
int16_t raw = (((uint16_t)buff[0] << 8) | buff[1]);
sensor->temp = raw / 32 * 0.125;
return UT_SENSORSTATUS_OK;
}