Fixed bug in Intel AMT password testing system.
This commit is contained in:
parent
effb43643d
commit
1d7635a0e4
@ -313,7 +313,8 @@ module.exports.CreateAmtManager = function (parent) {
|
||||
if ((typeof mesh.amt.password == 'string') && (mesh.amt.password != '')) { password = mesh.amt.password; }
|
||||
}
|
||||
}
|
||||
if (amtPolicy < 2) { ciraPolicy = 0; }
|
||||
if (amtPolicy == 0) { ciraPolicy = 0; } // If no policy, don't change CIRA state.
|
||||
if (amtPolicy == 1) { ciraPolicy = 1; } // If deactivation policy, clear CIRA.
|
||||
dev.policy = { amtPolicy: amtPolicy, ciraPolicy: ciraPolicy, badPass: badPass, password: password };
|
||||
|
||||
// Setup the monitored device
|
||||
@ -371,8 +372,8 @@ module.exports.CreateAmtManager = function (parent) {
|
||||
// Deactivate CCM.
|
||||
deactivateIntelAmtCCM(dev);
|
||||
} else {
|
||||
// Already deactivated or in ACM, do nothing.
|
||||
dev.consoleMsg("Done.");
|
||||
// Already deactivated or in ACM
|
||||
dev.consoleMsg("Done."); // TODO: We need to at least clear CIRA
|
||||
removeAmtDevice(dev);
|
||||
}
|
||||
return;
|
||||
@ -570,7 +571,7 @@ module.exports.CreateAmtManager = function (parent) {
|
||||
} else if (status == 401) {
|
||||
// Authentication error, see if we can use alternative credentials
|
||||
if ((dev.acctry == null) && (typeof dev.policy.password == 'string') && (dev.policy.password != '')) { dev.acctry = 'policy'; attemptInitialContact(dev); return; }
|
||||
if ((dev.acctry == null) || (dev.acctry == 'policy') && (obj.amtAdminAccounts[dev.domainid] != null) && (obj.amtAdminAccounts[dev.domainid].length > 0)) { dev.acctry = 0; attemptInitialContact(dev); return; }
|
||||
if (((dev.acctry == null) || (dev.acctry == 'policy')) && (obj.amtAdminAccounts[dev.domainid] != null) && (obj.amtAdminAccounts[dev.domainid].length > 0)) { dev.acctry = 0; attemptInitialContact(dev); return; }
|
||||
if ((dev.acctry != null) && (obj.amtAdminAccounts[dev.domainid] != null) && (obj.amtAdminAccounts[dev.domainid].length > (dev.acctry + 1))) { dev.acctry++; attemptInitialContact(dev); return; }
|
||||
|
||||
// If this devics is in CCM mode and we have a bad password reset policy, do it now.
|
||||
@ -1209,8 +1210,8 @@ module.exports.CreateAmtManager = function (parent) {
|
||||
const dev = stack.dev;
|
||||
if (isAmtDeviceValid(dev) == false) return; // Device no longer exists, ignore this request.
|
||||
if (status != 200) { dev.consoleMsg("Failed to create new MPS server (" + status + ")."); removeAmtDevice(dev); return; }
|
||||
if ((response.Body.MpServer == null) || (response.Body.MpServer.ReferenceParameters == null) || (response.Body.MpServer.ReferenceParameters.SelectorSet == null) || (response.Body.MpServer.ReferenceParameters.SelectorSet.Selector == null)) { dev.consoleMsg("Create new MPS server invalid response."); removeAmtDevice(dev); return; }
|
||||
dev.cira.mpsPresent = getItem(response.Body.MpServer.ReferenceParameters.SelectorSet.Selector, '@Name', 'Name').Value;
|
||||
console.log(dev.cira.mpsPresent);
|
||||
dev.consoleMsg("Created new MPS server.");
|
||||
addMpsPolicy(dev);
|
||||
});
|
||||
@ -1832,7 +1833,7 @@ module.exports.CreateAmtManager = function (parent) {
|
||||
delete dev.amtstack;
|
||||
UpdateDevice(dev);
|
||||
|
||||
if (dev.policy.amtPolicy == 1) { // CCM deactivation policy, we are done.
|
||||
if (dev.policy.amtPolicy == 1) { // Deactivation policy, we are done.
|
||||
dev.consoleMsg("Deactivation successful.");
|
||||
dev.consoleMsg("Done.");
|
||||
removeAmtDevice(dev);
|
||||
|
@ -9421,7 +9421,7 @@
|
||||
// Intel AMT setup
|
||||
var intelAmtPolicy = "No Policy";
|
||||
if (currentMesh.amt) {
|
||||
if (currentMesh.amt.type == 1) { intelAmtPolicy = 'Deactivate Client Control Mode (CCM)'; }
|
||||
if (currentMesh.amt.type == 1) { intelAmtPolicy = 'Deactivate'; }
|
||||
else if (currentMesh.amt.type == 2) {
|
||||
intelAmtPolicy = "Simple Client Control Mode (CCM)";
|
||||
if (currentMesh.amt.cirasetup == 2) { intelAmtPolicy += " + CIRA"; }
|
||||
@ -9519,7 +9519,7 @@
|
||||
if (xxdialogMode) return;
|
||||
var x = '', acmoption = '';
|
||||
if ((features & 0x100000) != 0) { acmoption = '<option value=3>' + "Simple Admin Control Mode (ACM)" + '</option>'; }
|
||||
x += addHtmlValue("Type", '<select id=dp20amtpolicy style=width:230px onchange=p20editMeshAmtChange()><option value=0>' + "No Policy" + '</option><option value=1>' + "Deactivate Client Control Mode (CCM)" + '</option><option value=2>' + "Simple Client Control Mode (CCM)" + '</option>' + acmoption + '<option value=4>' + "Fully Automatic" + '</option></select>');
|
||||
x += addHtmlValue("Type", '<select id=dp20amtpolicy style=width:230px onchange=p20editMeshAmtChange()><option value=0>' + "No Policy" + '</option><option value=1>' + "Deactivate" + '</option><option value=2>' + "Simple Client Control Mode (CCM)" + '</option>' + acmoption + '<option value=4>' + "Fully Automatic" + '</option></select>');
|
||||
x += '<div id=dp20amtpolicydiv></div>';
|
||||
setDialogMode(2, "Intel® AMT Policy", 3, p20editMeshAmtEx, x);
|
||||
if (currentMesh.amt) { Q('dp20amtpolicy').value = currentMesh.amt.type; }
|
||||
@ -9553,7 +9553,7 @@
|
||||
}
|
||||
}
|
||||
if (ptype == 0) { x = '<table style=padding-top:4px><tr><td><img style=padding-right:8px src=images/rcheckbox60.png width=60 height=60><td>' + "When this policy is selected, Intel® AMT is not managed by this server. Intel AMT can still be used by manually activating and configuring it." + '</table>'; }
|
||||
if (ptype == 1) { x = '<table style=padding-top:4px><tr><td><img style=padding-right:8px src=images/rcheckbox60.png width=60 height=60><td>' + "When this policy is selected, any Intel® AMT in Client Control Mode (CCM) will be deactivated. Devices in Admin Control Mode (ACM) can still be managed manually." + '</table>'; }
|
||||
if (ptype == 1) { x = '<table style=padding-top:4px><tr><td><img style=padding-right:8px src=images/rcheckbox60.png width=60 height=60><td>' + "When this policy is selected, any Intel® AMT in Client Control Mode (CCM) will be deactivated. Other devices will have CIRA cleared and can still be managed manually." + '</table>'; }
|
||||
if (ptype == 4) { x = '<table style=padding-top:4px><tr><td><img style=padding-right:8px src=images/checkbox60.png width=60 height=60><td>' + "This is the recommanded policy. Intel® AMT activation and management is completely automated and the server will attempt to make best possible use of hardware management." + '</table>'; }
|
||||
QH('dp20amtpolicydiv', x);
|
||||
setTimeout(dp20amtValidatePolicy, 1);
|
||||
|