git.iko.soy/distributed-process
on master help sign in
Fix comments
commit077ebd774922be0b131b928855a517d648284584 authorEdsko de Vries <edsko@edsko.net> dateThu 7 Jun 2012, 17:22 (14 years ago) parent059daf4
1 file changed+11−11
distributed-process/src/Control/Distributed/Process.hs+11−11
distributed-process/src/Control/Distributed/Process.hs+11−11
@@ -213,17 +213,17 @@ linkProcess = undefined
213213
214214-- | The different kinds of monitoring available between processes.
215215data MonitorAction =
216− -- ^ MaMonitor means that the monitor process will be sent a
216+ -- MaMonitor means that the monitor process will be sent a
217217 -- ProcessMonitorException message when the monitee terminates for any
218218 -- reason.
219219 MaMonitor
220− -- ^ MaLink means that the monitor process will receive an asynchronous
220+ -- MaLink means that the monitor process will receive an asynchronous
221221 -- exception of type ProcessMonitorException when the monitee terminates
222222 -- for any reason
223223 | MaLink
224− -- ^ MaLinkError means that the monitor process will receive an
225− -- asynchronous exception of type ProcessMonitorException when the monitee
226− -- terminates abnormally
224+ -- MaLinkError means that the monitor process will receive an asynchronous
225+ -- exception of type ProcessMonitorException when the monitee terminates
226+ -- abnormally
227227 | MaLinkError
228228 deriving (Typeable, Show, Ord, Eq)
229229
@@ -239,17 +239,17 @@ data ProcessMonitorException = ProcessMonitorException ProcessId SignalReason
239239-- | Part of the notification system of process monitoring, indicating why the
240240-- monitor is being notified.
241241data SignalReason =
242− -- ^ the monitee terminated normally
242+ -- the monitee terminated normally
243243 SrNormal
244− -- ^ the monitee terminated with an uncaught exception, which is given as a
244+ -- the monitee terminated with an uncaught exception, which is given as a
245245 -- string
246246 | SrException String
247− -- ^ the monitee is believed to have ended or be inaccessible, as the node
248− -- on which its running is not responding to pings. This may indicate a
247+ -- the monitee is believed to have ended or be inaccessible, as the node on
248+ -- which its running is not responding to pings. This may indicate a
249249 -- network bisection or that the remote node has crashed.
250250 | SrNoPing
251− -- ^ SrInvalid: the monitee was not running at the time of the attempt to
252− -- establish monitoring
251+ -- the monitee was not running at the time of the attempt to establish
252+ -- monitoring
253253 | SrInvalid
254254 deriving (Typeable,Show)
255255