Just maching all network interfaces caused many breakages, see #18962
and #71106.
We already don't support the global networking.useDHCP,
networking.defaultGateway(6) options if networking.useNetworkd is
enabled, but direct users to configure the per-device
networking.interfaces.<name?>.… options.
We don't want to ignore config that can mess up machines. In general
this should always fail evaluation, as you think you are changing
behaviour and don't, which can easily create run-time errors we can
catch early.
With systemd version 243 network units with empty match block will
generate warnigs. The reasoning seems to be that the intended behaviour
is hard to infere. Being explicit about really meaning any interface is
the reasonable thing here.
We want to get rid of this mechanism in the long run but as long as we
do not have a replacement we should stick with it and keep it in
reasonable good shape.
This fixes a serious bug on NixOS with swraid where mdadm arrays weren't
properly stopped on shutdown. Rather than fixing the unit by adding
`Before=final.target` we completely move to upstream units, which uses
systemd shutdown hooks instead. This also drives down maintenance costs
for us.
Introduces a trim timer similar to the fstrim service.
According to zpool(8) for consumer hardware periodic manual TRIM
is preferred over automatic TRIM that ZFS implements.
The period of one week is based on recommendations of fstrim.
This is a refactor of how resolvconf is managed on NixOS. We split it
into a separate service which is enabled internally depending on whether
we want /etc/resolv.conf to be managed by it. Various services now take
advantage of those configuration options.
We also now use systemd instead of activation scripts to update
resolv.conf.
NetworkManager now uses the right option for rc-manager DNS
automatically, so the configuration option shouldn't be exposed.
Same as zfsUnstable for the moment.
We still keep the zfsUnstable expression as we likely
need it in the near future again.
Also remove spl since it is no longer needed.
With systemd v242 using the `Gateway` attribute of the `[Network]`
section will lead to "onlink" routes on all the device that are matched
by the default configuration (typically all devices) causing multiple
default routes (even on localhost).
We can only avoid that - while keeping our default route option - when
we mark the route as explicitly not on link. Only gateways that are
within a subnet of one of the assigned interface addresses will be
installed into the routing table.
Assert that autoResize is only used when fsType is explicitly set to a
supported filesystem: if it's set to "auto", the default, the required
resizing tools won't be copied into the initrd even if the actual
filesystem is supported.
27982b408e introduced a bug when
refactoring the encrypted-devices module, causing some encrypted
filesystem options to not be recognized anymore.
See e.g. https://hydra.nixos.org/build/88145490
This adds a NixOS option for setting the CPU max and min frequencies
with `cpufreq`. The two options that have been added are:
- `powerManagement.cpufreq.max`
- `powerManagement.cpufreq.min`
It also adds an alias to the `powerManagement.cpuFreqGovernor` option as
`powerManagement.cpufreq.governor`. This updates the installer to use
the new option name. It also updates the manual with a note about
the new name.
When a bridge interface was reconfigured, running containers using
this bridge lost connectivity: restarting network-addresses-brN.service
triggered a restart of network-setup.service via a "partOf" relationship
introduced in 07e0c0e0a2.
This in turn restarted brN-netdev.service.
The bridge was thus destroyed and recreated with the same name but a new
interface id, causing attached veth interfaces to lose their connection.
This change removes the "partOf" relationship between
network-setup.service and network-addresses-brN.service for all bridges.
1. Simplify the command by reading directly from /etc/machine-id which
is already a random, lower-case hex string
2. Previously, the command output could be too short because of missing
leading digits. This is now fixed.
when the parent interface of a vlan interface is not up (yet), ip link cannot bring the vlan interface up
the vlan interface will be automatically brought up when the parent interface is up later
fixNixOS/nixpkgs#28620
With a config like
{
networking.interfaces."lo".ip4 = [
{ address = "10.8.8.8"; prefixLength = 32; }
];
}
a nixos-rebuild switch would take a long time, and you'd see:
$ systemctl list-jobs
JOB UNIT TYPE STATE
734400 network-interfaces.target start waiting
734450 sys-subsystem-net-devices-lo.device start running
734449 network-link-lo.service start waiting
and:
systemd[1]: sys-subsystem-net-devices-lo.device: Job sys-subsystem-net-devices-lo.device/star>
systemd[1]: sys-subsystem-net-devices-lo.device: Job sys-subsystem-net-devices-lo.device/star>
systemd[1]: Timed out waiting for device sys-subsystem-net-devices-lo.device.
This removes the device dependency for `lo` and fixes this bug.
Closes#7227
fixes#41838
At the moment it works fine for "file://" keys, but does not work for
dataPools with "prompt" keys, because the passphrase cannot be entered
(yet).
Resolved the following conflicts (by carefully applying patches from the both
branches since the fork point):
pkgs/development/libraries/epoxy/default.nix
pkgs/development/libraries/gtk+/3.x.nix
pkgs/development/python-modules/asgiref/default.nix
pkgs/development/python-modules/daphne/default.nix
pkgs/os-specific/linux/systemd/default.nix
Users were confused that the error message said config.networking.hostId, and indeed that did nothing to fix their problem.
Update the error message to specify the option they should actually set.
Reverse the PartOf dependency between network-setup and network-addresses-*
This was joint work of: @nh2, @domenkozar, @fpletz, @aszlig and @basvandijk
at the NixCon 2017 hackathon.
Currently, ecryptfs support is coupled to `security.pam.enableEcryptfs`, but one
might want to use ecryptfs without enabling the PAM functionality. This commit
splits it out into a `boot.supportedFilesystems` switch.
When autoFormat is enabled, in order to successfully create a filesystem,
certain filesystems require specific options to be passed to mkfs to prevent
it from asking questions. This commit sets default formatOptions to "-q"
for "jfs" and "reiserfs" filesystems for this purpose.
Resolves#29140.
powertop attempt to load some kernel modules like msr by calling
modprobe. This is the counterpart to
88e43eb39b which has the powertop
executable search PATH for modprobe rather than hardcoding /sbin, and
actually adds the directory containing modprobe to its PATH for the
systemd service.
This reverts commit 0c81594a29.
It's no longer needed since systemd-vconsole-setup enumerates all ttys
until it finds a suitable one since systemd v234.
Systemd is complaining that it can't delay the startup of device units.
We have a before dependency on the respective device unit for every
netdev service, which doesn't make any sense because we create the
actual interface in this service.
Previously, depending on the environment and the type of interface that
was created, the configured IPs of an interface wouldn't be applied on a
nixos-rebuild switch. It works after a reboot.
This patch ensures that the network-addresses service is started
either via the network-link service or if the networking target is
activated (i.e. on system activation).
Fixes#28474#16230.
This reverts commit 670b4e29ad. The change
added in this commit was controversial when it was originally suggested
in https://github.com/NixOS/nixpkgs/pull/29205. Then that PR was closed
and a new one opened, https://github.com/NixOS/nixpkgs/pull/29503,
effectively circumventing the review process. I don't agree with this
modification. Adding an option 'resolveLocalQueries' to tell the locally
running name server that it should resolve local DNS queries feels
outright nuts. I agree that the current state is unsatisfactory and that
it should be improved, but this is not the right way.
(cherry picked from commit 23a021d12e)
This includes fuse-common (fusePackages.fuse_3.common) as recommended by
upstream. But while fuse(2) and fuse3 would normally depend on
fuse-common we can't do that in nixpkgs while fuse-common is just
another output from the fuse3 multiple-output derivation (i.e. this
would result in a circular dependency). To avoid building fuse3 twice I
decided it would be best to copy the shared files (i.e. the ones
provided by fuse(2) and fuse3) from fuse-common to fuse (version 2) and
avoid collision warnings by defining priorities. Now it should be
possible to install an arbitrary combination of "fuse", "fuse3", and
"fuse-common" without getting any collision warnings. The end result
should be the same and all changes should be backwards compatible
(assuming that mount.fuse from fuse3 is backwards compatible as stated
by upstream [0] - if not this might break some /etc/fstab definitions
but that should be very unlikely).
My tests with sshfs (version 2 and 3) didn't show any problems.
See #28409 for some additional information.
[0]: https://github.com/libfuse/libfuse/releases/tag/fuse-3.0.0
Currently the `rpc-gssd.service` has a `ConditionPathExists` clause that can
never be met, because it's looking for stateful data inside `/nix/store`.
`auth-rpcgss-module.service` also only starts if this file exists.
FixesNixOS/nixpkgs#29509.
When the user specifies the networking.nameservers setting in the
configuration file, it must take precedence over automatically
derived settings.
The culprit was services.bind that made the resolver set to
127.0.0.1 and ignore the nameserver setting.
This patch adds a flag to services.bind to override the nameserver
to localhost. It defaults to true. Setting this to false prevents the
service.bind and dnsmasq.resolveLocalQueries settings from
overriding the users' settings.
Also, when the user specifies a domain to search, it must be set in
the resolver configuration, even if the user does not specify any
nameservers.
(cherry picked from commit 670b4e29ad)
This commit was accidentally merged to 17.09 but was intended for
master. This is the cherry-pick to master.
Previously services depending on network-online.target would wait until
dhcpcd times out if it was enabled and a static network address
configuration was used. Setting the default gateway statically is enough
for the networking to be considered online.
This also adjusts the relevant networking tests to wait for
network-online.target instead of just network.target.
Boot fails when a keyfile is configured for all encrypted filesystems
and no other luks devices are configured. This is because luks support is only
enabled in the initrd, when boot.initrd.luks.devices has entries. When a
fileystem has a keyfile configured though, it is setup by a custom
command, not by boot.initrd.luks.
This commit adds an internal config flag to enable luks support in the
initrd file, even if there are no luks devices configured.
Adds /dev/disk/by-{id,label}/* symlinks for bcache device nodes, in the
final rootfs.
Symlinks will only be created for bcache devices that contain
filesystems. So if you have a blank bcache device or run LVM on top of
bcache you will not get this kind of symlink.
This reduces the time window during which IP addresses are gone during
switch-to-configuration. A complication is that with stopIfChanged =
true, preStop would try to delete the *new* IP addresses rather than
the old one (since the preStop script now runs after the switch to the
new configuration). So we now record the actually configured addresses
in /run/nixos/network/addresses/<interface>. This is more robust in
any case.
Issue https://github.com/NixOS/nixops/issues/640.
And adopt the tests to add an interface and remove it again.
It should work when deactivating rstp, it will not work when activating
rstp for the first bridge as then the userspace daemon is not yet
available. But once one bridge is active with stp, it should work with
the reload for any further bridge.
Fixes#21745. Also see #22547.
After the change of the bonding options, the examples were not quite correct.
The diff is over-the top because the new `let` needs everything indented.
Also add a small docstring to the `networkd` attr in the networking test.
reason: after the upgrade of iputils from 20151218 to 20161105
functionality of ping6 and tracepath6 was merged into ping and tracepath.
Ping is now mostly a drop-in replacment for ping6, except that selecting a
specific interface is done by encoding it into the address (ex.: fe80::1%eth0)
rather then specifing it with the `-I` flag.
Since the bonds interface changed to a lot more possible values we create a
mapping of kernel bond attribute names and values to networkd attributes.
Those match for the most part, but have to transformed slightly.
There is also an assert that unknown options won’t slip through silently.
Until now the four attributes available very selectively provided a small
subset, while copying upstream documentation.
We make driver options an arbitrary key-value set and point to kernel
documentation, which is always up-to-date. This way every option can be set.
The four already existing options are deprecated with a warning.
Previously, netdev units for network interfaces defined in the nixos
configurations would bindTo the systemd device unit of the interface if
not in a container.
In situations where you switch to a new nixos configration with changes
to network-setup.service (like nameservers) and have stacked interfaces
like vlans on a bond, it would fail to propagate restarts to the netdevs
correctly resulting with broken networking. The bond would be present
but no vlan interfaces rendering the machine unreachable.
My fear is that the udev events fail to propagate correctly while a systemd
transaction that is also restarting the triggered netdev service is running.
This commit changes this behaviour so netdev services bindTo other netdev
services if present and otherwise fall back to the previous behaviour.
We also noticed that stacked interfaces would sometimes seemingly be stopped
in the wrong order. For instance in the above example, the bond interface
would be deleted before the vlan interfaces resulting in the vlan interfaces
not being present when their service is being stopped. This would cause the
systemd transaction to fail and thus break networking. Their postStop hooks
are now allowed to fail as we have reached the desired state.
Regression introduced by 0cb487ee04.
This changed the result for defaultGateway to be a submodule instead of
just a plain string, so instead of using just cfg.defaultGateway we need
to pass cfg.defaultGateway.address now.
Signed-off-by: aszlig <aszlig@redmoonstudios.org>
Cc: @abbradar