mirror of
https://github.com/nicolargo/glances.git
synced 2024-12-23 17:22:46 +03:00
43 lines
1.3 KiB
ReStructuredText
43 lines
1.3 KiB
ReStructuredText
.. _sensors:
|
|
|
|
Sensors
|
|
=======
|
|
|
|
*Availability: Linux*
|
|
|
|
.. image:: ../_static/sensors.png
|
|
|
|
Glances can display the sensors information using ``psutil``,
|
|
``hddtemp`` and ``batinfo``:
|
|
- motherboard and CPU temperatures
|
|
- hard disk temperature
|
|
- battery capacity
|
|
|
|
There is no alert on this information.
|
|
|
|
.. note 1::
|
|
Limit values and sensors alias names can be defined in the
|
|
configuration file under the ``[sensors]`` section.
|
|
|
|
.. note 2::
|
|
The support for multiple batteries is only available if
|
|
you have the batinfo Python lib installed on your system
|
|
because for the moment PSUtil only support one battery.
|
|
|
|
.. note 3::
|
|
If a sensors has temperature and fan speed with the same name unit,
|
|
it is possible to alias it using:
|
|
unitname_temperature_core_alias=Alias for temp
|
|
unitname_fan_speed_alias=Alias for fan speed
|
|
|
|
.. note 4::
|
|
If a sensors has multiple identical features names (see #2280), then
|
|
Glances will add a suffix to the feature name.
|
|
For example, if you have one sensor with two Composite features, the
|
|
second one will be named Composite_1.
|
|
|
|
.. note 5::
|
|
The plugin could crash on some operating system (FreeBSD) with the
|
|
TCP or UDP blackhole option > 0 (see issue #2106). In this case, you
|
|
should disable the sensors (--disable-plugin sensors or from the
|
|
configuration file). |