home-assistant: use SIGINT instead of SIGTERM to shut down (#49571)
hass will ignore the standard SIGTERM sent by systemd during stop/restart and we
then have to wait for the timeout after which systemd will forcefully kill the
process.
If instead if we send SIGINT, hass will shut down nicely.
There are many issues reported upstream about the inability to shut down/restart
and it is *supposed* to work with SIGTERM but doesn't.
commitdb1a40a882987f94f8580b2b219a5857a3789a77
authorPeter Hoeg <peter@hoeg.com>
dateThu 1 Nov 2018, 23:39 (8 years ago)
parent7b5a329
nixos/modules/services/misc/home-assistant.nix+1
@@ -157,6 +157,7 @@ in {
157157 Restart = "on-failure";
158158 ProtectSystem = "strict";
159159 ReadWritePaths = "${cfg.configDir}";
160+ KillSignal = "SIGINT";
160161 PrivateTmp = true;
161162 RemoveIPC = true;
162163 };