* Enable log-to-file configuration PR #7825 enabled parallel logging to a file with a much more fine-grained log level by default. However, logging at `TRACE` level on Windows appears to be still problematic. This PR reduced the default log level to file from `DEBUG` to `TRACE` and allows to control it via an environment variable if one wishes to change the verbosity without making code changes. * PR comments
12 KiB
layout | title | category | tags | order | |||
---|---|---|---|---|---|---|---|
developer-doc | Logging Service | infrastructure |
|
6 |
Logging
The Enso project features a centralised logging service to allow for the aggregation of logs from multiple components. This service can be started with one of the main components, allowing other components to connect to it. The service aggregates all logs in one place for easier analysis of the interaction between components. Components can also log to console or files directly without involving the centralized logging service.
Configuration
The logging settings should be placed under the logging-service
key of the
application.conf
config. Each of the main components can customize format and
output target via section in application.conf
configuration file. The
configuration is using HOCON-style, as defined by
lightbend/config. Individual values
accepted in the config are inspired by SLF4J's properties, formatting and
implementations.
The configuration has two main sections:
- custom log levels
- applications' appenders (also known as configuration of log events output target)
During component's setup, its application.conf
config file is parsed. The
config's keys and values are validated and, if correct, the parsed
representation is available as an instance of
org.enso.logger.config.LoggingServiceConfig
class. The class encapsulates the
logging-service
section of application.conf
file and is used to
programmatically initialize loggers.
As per configuration schema any key can have a default value that can be overridden by an environment variable. For example
{
host = localhost
host = $ENSO_HOST
}
defines a host
key once, except that ENSO_HOST
values takes a precedence if
it is defined during loading of the config file.
Custom Log Levels
The logging-service.logger
configuration provides an ability to override the
default application log level for particular loggers. In the logger
subconfig
the key specifies the logger name (or it's prefix) and the value specifies the
log level for that logger.
logging-service.logger {
akka.actor = info
akka.event = error
akka.io = error
slick {
jdbc.JdbcBackend.statement = debug
"*" = error
}
}
For example, the config above limits all akka.actor.*
loggers to the info
level logging, and akka.event.*
loggers can emit only the error level
messages.
Config supports globs (*
). For example, the config above sets
jdbc.JdbcBackend.statement
SQL statements logging to debug level, and the rest
of the slick loggers to error level.
Additionally, custom log events can be provided during runtime via system properties, without re-packaging the updated config file. For example
akka.actor = info;
is equivalent to
-Dakka.actor.Logger.level=info
Any custom log level is therefore defined with -Dx.y.Z.Logger.level
where x
,
y
and Z
refer to the package elements and class name, respectively. System
properties always have a higher priority over those defined in the
application.conf
file.
Appenders
Log output target is also configured in the application.conf
files in the
"appenders" section ("appender" is equivalent to java.util.logging.Handler
semantics). Each appender section can provide further required and optional
key/value pairs, to better customize the log target output.
Currently supported are
- console appender - the most basic appender that prints log events to stdout
- file appender - appender that writes log events to a file, with optional rolling file policy
- socket appender - appender that forwards log events to some logging server
- sentry.io appender - appender that forwards log events to a sentry.io service
The appenders are defined by the logging-service.appenders
. Currently only a
single appender can be selected at a time. The selection may also be done via an
environmental variable but it depends on which component we are executing.
project-manager
- project manager by default starts a centralized logging server that collects logs (as defined inlogging-service.server
config key) and the logs output can be overwritten byENSO_LOGSERVER_APPENDER
env variablelauncher
orrunner
- the default log output can be overwritten by defining theENSO_APPENDER_DEFAULT
env variable
For example, for the project manager to output to console
one simply executes
ENSO_LOGSERVER_APPENDER=console ./project-manager
Format
The pattern follows the classic's PatternLayout format.
Appenders that store/display log events can specify the format of the log
message via pattern
field e.g.
appenders = [
{
name = "console"
pattern = "[%level{lowercase=true}] [%d{yyyy-MM-dd'T'HH:mm:ssXXX}] [%logger] %msg%n%nopex"
}
...
]
File Appender
Enabled with ENSO_APPENDER_DEFAULT=file
environment variable.
File appender directs all log events to a log file:
{
name = "file"
append = <boolean, optional>
immediate-flush = <boolean, optional>
pattern = <string, optional>
rolling-policy {
max-file-size = <string, optional>
max-history = <int, optional>
max-total-size = <string, optional>
}
}
Rolling policy is a fully optional property of File Appender that would trigger
automatic log rotation. All properties are optional with some reasonable
defaults if missing (defined in org.enso.logger.config.FileAppender
config
class).
Socket Appender
Enabled with ENSO_APPENDER_DEFAULT=socket
environment variable.
Configuration
{
name = "socket"
hostname = <string, required>
port = <string, required>
}
The two fields can be overridden via environment variables:
hostname
has an equivalent$ENSO_LOGSERVER_HOSTNAME
variableport
has an equivalent$ENSO_LOGSERVER_PORT
variable
Sentry Appender
Enabled with ENSO_APPENDER_DEFAULT=sentry
environment variable.
{
name = "sentry"
dsn = <string, required>
flush-timeout = <int, optional>
debug = <boolean, optional>
}
Sentry's Appender has a single required field, dsn
. The dsn
value can be
provided via an environment variable ENSO_APPENDER_SENTRY_DSN
. flush-timeout
determines how often logger should send its collected events to sentry.io
service. If debug
value is true
, logging will print to stdout additional
trace information of the logging process itself.
JVM Architecture
Enso's logging makes use of two logging APIs - java.util.logging
and
org.slf4j
. The former is being used Truffle runtime, which itself relies on
jul
, while the latter is used everywhere else. The implementation of the
logging is using off the shelf Logback
implementation with some custom setup
methods. The two APIss cooperate by essentially forwarding log messages from the
former to the latter.
While typically any SLF4J customization would be performed via custom
LoggerFacotry
and Logger
implementation that is returned via a
StaticLoggerBinder
instance, this is not possible for our use-case:
- file logging requires Enso-specific directory which is only known during runtime
- centralized logging
- modifying log levels without recompilation
SLF4J Interface
The user code must not be calling any of the underlying implementations, such as Log4J or Logback, and should only request loggers via factory methods.
One can use the org.slf4j.LoggerFactory
directly to retrieve class-specific
logger. For Scala code, it is recommended to use the
com.typesafe.scalalogging.Logger
instead which wraps the SLF4J logger with
macros that compute the log messages only if the given logging level is enabled,
and allows much prettier initialisation.
package foo;
import org.slf4j.Logger;
import org.slf4j.LoggerFactory;
public class Foo {
private Logger logger = LoggerFactory.getLogger(Foo.class);
public void bar() {
logger.info("Hello world!");
}
}
Setting Up Logging
The org.slf4j.Logger
instances have to know where to send log events. This
setting is typically performed once, when the service starts, and applies
globally during its execution. Currently, it is not possible to dynamically
change where log events are being stored. The main (abstract) class used for
setting up logging is org.enso.logger.LoggerSetup
. An instance of that class
can be retrieved with the thread-safe org.enso.logger.LoggerSetup.get
factory
method. org.enso.logger.LoggerSetup
provides a number of setupXYZAppender
methods that will direct loggers to send log events to an XYZ
appender.
Setting a specific hard-coded appender programmatically should however be
avoided by the users. Instead, one should invoke one of the overloaded setup
variants that initialize loggers based on the provided logging-service
configuration.
package foo;
import org.enso.logger.LoggerSetup;
import org.slf4j.event.Level;
public class MyService {
private Logger logger = LoggerFactory.getLogger(Foo.class);
...
public void start(Level logLevel) {
LoggerSetup.get().setup(logLevel);
logger.info("My service is starting...");
...
}
...
}
org.enso.logging.LoggingSetupHelper
class was introduced to help with the most
common use cases - establishing a file-based logging in the Enso's dedicated
directories or connecting to an existing logging server once it starts accepting
connections. That is why services don't call LoggerSetup
directly but instead
provide a service-specific implementation of
org.enso.logging.LoggingSetupHelper
. LoggingSetupHelper
and LoggerSetup
provide teardown
methods to properly dispose of log events.
Log Masking
Logs should not contain personally identifiable information (PII). The following is considered PII:
- User code
- Values of executed expressions
- Values of user environment variables. Although variable names are not considered PII and can be logged.
- File paths inside the user project directory. System and distribution paths and a path to the user project can be logged.
Project logging library implements masking of PII. To utilize it
- Logged object should implement an interface that defines custom log-string representation of this object
- The logging should be performed by supplying a template string with
{}
placeholders, and the argumentslog.debug("Created {} at [{}].", obj, path)
String interpolation in log statements s"Created $obj"
should be avoided
because it uses default toString
implementation and can leak critical
information even if the object implements custom interface for masked logging.
Logging in Tests
The Logging Service provides a helper function TestLogger.gatherLogs
that will
execute the closure and collect all logs reported in the specified class. That
way it can verify that all logs are being reported within the provided code.
Logging to file
By default Enso will attempt to persist (verbose) logs into a designated log
file. This means that even though a user might be shown WARNING
level logs in
the console, logs with up to DEBUG
level will be dumped into the log file. A
user can disable this parallel logging to a file by setting the environment
variable:
ENSO_LOG_TO_FILE=false project-manager ...
Users can also modify the default maximal log level, DEBUG
, used when logging
to a log file by setting the environment variable:
ENSO_LOG_TO_FILE_LOG_LEVEL=trace project-manager ...